Geovision GV-R1352 Guía de instalación Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 21
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
5.3 Configuring the Beeper and LED Settings for Each Door/Gate
After connecting the wires for beeper or LED, specify the conditions to trigger the beeper and
LED on the GV-AS210 / 2110 / 400 / 410 / 4110 / 810 / 8110 Web interface.
1. On the controller Web interface, click Output Setting. The page below appears.
2. Find the output wired to the beeper or LED and specify up to 2 alarm conditions to set off
the beeper or LED.
a. Output Type: Select Normal, Toggle or Pulse. If you select Pulse, you can specify
the number of seconds to trigger the beeper or LED.
b. Output Conditions: Select the door and the alarm conditions to trigger the beeper
or LED. Up to 2 sets of output conditions can be set.
3. If you have wired the beeper or LED to outputs 9 ~ 16 on GV-AS400, select a door and
select Beeper, Green LED, Red LED or Invert Red LED.
February 6, 2015
16
Beeper: Enables the external control of Beeper.
Green LED: Changes the standby color to blue. When a card is read, the LED
flashes green.
RED LED: Changes the standby color to red. When a card is read, the LED flashes
blue.
Invert Red LED: Changes the standby color to blue. When a card is granted access,
the LED flashes red.
4. Click Submit.
Vista de pagina 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21

Comentarios a estos manuales

Sin comentarios